{"product_id":"siemens-sbh2016dv-1600a-frame-3-pole-600v-lsig-drawout-breaker-24v-operator","title":"Siemens SBH2016DV 1600A Frame 3-Pole 600V LSIG Drawout Breaker – 24V Operator","description":"\u003cp data-start=\"141\" data-end=\"417\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"145\" data-end=\"166\"\u003eSiemens SBH2016DV\u003c\/strong\u003e is a three-pole, 600V industrial systems breaker built on the Siemens \u003cstrong data-start=\"237\" data-end=\"256\"\u003eSBH 1600A frame\u003c\/strong\u003e. This unit features electronic LSIG protection and a stationary drawout configuration for use in compatible Siemens switchgear and power-distribution equipment.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"419\" data-end=\"570\"\u003eThis specific breaker is equipped with a \u003cstrong data-start=\"460\" data-end=\"485\"\u003e24V electric operator\u003c\/strong\u003e, \u003cstrong data-start=\"487\" data-end=\"505\"\u003e24V shunt trip\u003c\/strong\u003e, auxiliary switches, bell alarm and stationary drawout hardware.\u003c\/p\u003e\n\u003cp data-start=\"572\" data-end=\"819\"\u003eThe final continuous-current rating must be confirmed from the installed rating plug shown on the breaker’s front trip unit. The \u003cstrong data-start=\"701\" data-end=\"750\"\u003e1600A designation is the maximum frame rating\u003c\/strong\u003e and should not automatically be treated as the installed amp rating.\u003c\/p\u003e\n\u003ch2 data-section-id=\"pxfjfj\" data-start=\"821\" data-end=\"851\"\u003eConfirmed Nameplate Details\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"853\" data-end=\"1449\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"853\" data-end=\"880\"\u003e\n\u003ctr data-start=\"853\" data-end=\"880\"\u003e\n\u003cth data-start=\"853\" data-end=\"869\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"869\" data-end=\"880\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"891\" data-end=\"1449\"\u003e\n\u003ctr data-start=\"891\" data-end=\"917\"\u003e\n\u003ctd data-start=\"891\" data-end=\"906\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"906\" data-end=\"917\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"918\" data-end=\"952\"\u003e\n\u003ctd data-start=\"918\" data-end=\"935\" data-col-size=\"sm\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"935\" data-end=\"952\"\u003e\u003cstrong data-start=\"937\" data-end=\"950\"\u003eSBH2016DV\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"953\" data-end=\"983\"\u003e\n\u003ctd data-start=\"953\" data-end=\"976\" data-col-size=\"sm\"\u003eSystems Breaker Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"976\" data-end=\"983\"\u003eSBH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"984\" data-end=\"1014\"\u003e\n\u003ctd data-start=\"984\" data-end=\"997\" data-col-size=\"sm\"\u003eFrame Size\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"997\" data-end=\"1014\"\u003e1600A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1015\" data-end=\"1028\"\u003e\n\u003ctd data-start=\"1015\" data-end=\"1023\" data-col-size=\"sm\"\u003ePoles\u003c\/td\u003e\n\u003ctd data-start=\"1023\" data-end=\"1028\" data-col-size=\"sm\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1029\" data-end=\"1058\"\u003e\n\u003ctd data-start=\"1029\" data-end=\"1047\" data-col-size=\"sm\"\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1047\" data-end=\"1058\"\u003e600 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1059\" data-end=\"1092\"\u003e\n\u003ctd data-start=\"1059\" data-end=\"1070\" data-col-size=\"sm\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1070\" data-end=\"1092\"\u003eStationary drawout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1093\" data-end=\"1134\"\u003e\n\u003ctd data-start=\"1093\" data-end=\"1118\" data-col-size=\"sm\"\u003eDrawout Catalog Number\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1118\" data-end=\"1134\"\u003e\u003cstrong data-start=\"1120\" data-end=\"1132\"\u003eSBH20DFV\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1135\" data-end=\"1160\"\u003e\n\u003ctd data-start=\"1135\" data-end=\"1151\" data-col-size=\"sm\"\u003eSerial Number\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1151\" data-end=\"1160\"\u003e42534\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1161\" data-end=\"1198\"\u003e\n\u003ctd data-start=\"1161\" data-end=\"1179\" data-col-size=\"sm\"\u003eTrip Protection\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1179\" data-end=\"1198\"\u003eElectronic LSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1199\" data-end=\"1233\"\u003e\n\u003ctd data-start=\"1199\" data-end=\"1219\" data-col-size=\"sm\"\u003eElectric Operator\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1219\" data-end=\"1233\"\u003e\u003cstrong data-start=\"1221\" data-end=\"1231\"\u003eSBEO24\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1234\" data-end=\"1261\"\u003e\n\u003ctd data-start=\"1234\" data-end=\"1247\" data-col-size=\"sm\"\u003eShunt Trip\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1247\" data-end=\"1261\"\u003e\u003cstrong data-start=\"1249\" data-end=\"1259\"\u003eSBST24\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1262\" data-end=\"1296\"\u003e\n\u003ctd data-start=\"1262\" data-end=\"1283\" data-col-size=\"sm\"\u003eAuxiliary Switches\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1283\" data-end=\"1296\"\u003e\u003cstrong data-start=\"1285\" data-end=\"1294\"\u003eSBAS8\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1297\" data-end=\"1323\"\u003e\n\u003ctd data-start=\"1297\" data-end=\"1310\" data-col-size=\"sm\"\u003eBell Alarm\u003c\/td\u003e\n\u003ctd data-start=\"1310\" data-end=\"1323\" data-col-size=\"sm\"\u003eInstalled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1324\" data-end=\"1367\"\u003e\n\u003ctd data-start=\"1324\" data-end=\"1350\" data-col-size=\"sm\"\u003eRemote Closing Solenoid\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1350\" data-end=\"1367\"\u003eNot indicated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1368\" data-end=\"1408\"\u003e\n\u003ctd data-start=\"1368\" data-end=\"1391\" data-col-size=\"sm\"\u003eUndervoltage Release\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1391\" data-end=\"1408\"\u003eNot indicated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1409\" data-end=\"1449\"\u003e\n\u003ctd data-start=\"1409\" data-end=\"1432\" data-col-size=\"sm\"\u003eDisplay Module Relay\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1432\" data-end=\"1449\"\u003eNot indicated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-section-id=\"1qpx70j\" data-start=\"1451\" data-end=\"1475\"\u003eInstalled Accessories\u003c\/h2\u003e\n\u003cul data-start=\"1477\" data-end=\"1640\"\u003e\n\u003cli data-section-id=\"1t0xbzq\" data-start=\"1477\" data-end=\"1507\"\u003e\u003cstrong data-start=\"1479\" data-end=\"1507\"\u003eSBEO24 electric operator\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"g4j3mm\" data-start=\"1508\" data-end=\"1541\"\u003e\u003cstrong data-start=\"1510\" data-end=\"1541\"\u003eSBST24 shunt-trip accessory\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"zhjv94\" data-start=\"1542\" data-end=\"1579\"\u003e\u003cstrong data-start=\"1544\" data-end=\"1579\"\u003eSBAS8 auxiliary-switch assembly\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1f13658\" data-start=\"1580\" data-end=\"1592\"\u003eBell alarm\u003c\/li\u003e\n\u003cli data-section-id=\"u0s8sp\" data-start=\"1593\" data-end=\"1640\"\u003e\u003cstrong data-start=\"1595\" data-end=\"1640\"\u003eSBH20DFV stationary drawout configuration\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1mp5zu7\" data-start=\"1642\" data-end=\"1672\"\u003eImportant Amp-Rating Notice\u003c\/h2\u003e\n\u003cp data-start=\"1674\" data-end=\"1792\"\u003eThe breaker frame is rated up to \u003cstrong data-start=\"1707\" data-end=\"1720\"\u003e1600 amps\u003c\/strong\u003e, but the actual operating current depends on the installed rating plug.\u003c\/p\u003e\n\u003cp data-start=\"1794\" data-end=\"1852\"\u003eUse this wording until the front rating plug is confirmed:\u003c\/p\u003e\n\u003cblockquote data-start=\"1854\" data-end=\"1938\"\u003e\n\u003cp data-start=\"1856\" data-end=\"1938\"\u003e\u003cstrong data-start=\"1856\" data-end=\"1938\"\u003eSiemens SBH2016DV, 1600A maximum frame, installed rating plug to be confirmed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp data-start=\"1940\" data-end=\"2025\"\u003eDo not advertise it as a fixed 1600A breaker unless a 1600A rating plug is installed.\u003c\/p\u003e\n\u003ch2 data-section-id=\"164os46\" data-start=\"2027\" data-end=\"2050\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cul data-start=\"2052\" data-end=\"2294\"\u003e\n\u003cli data-section-id=\"s5bc7u\" data-start=\"2052\" data-end=\"2084\"\u003eSiemens low-voltage switchgear\u003c\/li\u003e\n\u003cli data-section-id=\"41m0mp\" data-start=\"2085\" data-end=\"2108\"\u003eMain breaker sections\u003c\/li\u003e\n\u003cli data-section-id=\"r0me7j\" data-start=\"2109\" data-end=\"2134\"\u003eFeeder breaker sections\u003c\/li\u003e\n\u003cli data-section-id=\"g9bhw1\" data-start=\"2135\" data-end=\"2174\"\u003eIndustrial power-distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"433w68\" data-start=\"2175\" data-end=\"2211\"\u003eCommercial electrical distribution\u003c\/li\u003e\n\u003cli data-section-id=\"qzhenl\" data-start=\"2212\" data-end=\"2251\"\u003eReplacement and retrofit applications\u003c\/li\u003e\n\u003cli data-section-id=\"gzaare\" data-start=\"2252\" data-end=\"2294\"\u003eElectrically operated switchgear systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2296\" data-end=\"2458\"\u003eCompatibility must be confirmed using the complete breaker catalog number, cradle configuration, control voltage, secondary connections and installed accessories.\u003c\/p\u003e\n\u003ch2 data-section-id=\"efhg4w\" data-start=\"2460\" data-end=\"2484\"\u003eCondition Description\u003c\/h2\u003e\n\u003cp data-start=\"2486\" data-end=\"2712\"\u003e\u003cstrong data-start=\"2486\" data-end=\"2504\"\u003eReconditioned:\u003c\/strong\u003e Previously installed industrial circuit breaker that has been inspected, cleaned and mechanically operated. Electrical testing documentation may be provided when included with the sale or ordered separately.\u003c\/p\u003e\n\u003cp data-start=\"2714\" data-end=\"2840\"\u003eActual photographs should be used because rating plugs, trip units, accessories and cosmetic condition can vary between units.\u003c\/p\u003e","brand":"Ampstate Electric","offers":[{"title":"Default Title","offer_id":44377385205826,"sku":null,"price":19000.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0613\/8783\/3410\/files\/WhatsApp_Image_2026-07-21_at_11.30.04_AM__1_-removebg-preview-Photoroom.png?v=1784650329","url":"https:\/\/ampstate.ca\/products\/siemens-sbh2016dv-1600a-frame-3-pole-600v-lsig-drawout-breaker-24v-operator","provider":"Ampstate Electric","version":"1.0","type":"link"}