{"product_id":"siemens-scmd69800angt-800a-3-pole-600v-lsig-circuit-breaker","title":"Siemens SCMD69800ANGT 800A 3-Pole 600V LSIG Circuit Breaker","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSiemens SCMD69800ANGT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is an 800-amp, three-pole molded-case circuit breaker from the Siemens Sentron series. It is designed for heavy-duty commercial and industrial electrical-distribution applications requiring electronic overcurrent protection and a high interrupting capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe SCMD69800ANGT features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edigital solid-state LSIG trip unit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing long-time, short-time, instantaneous, and ground-fault protection. It is rated for operation at up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e600 Vac\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and provides an interrupting capacity of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e65 kAIC at 480 Vac\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis breaker uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebolt-on mounting configuration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is commonly used in compatible Siemens switchboards, distribution equipment, industrial enclosures, and replacement applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe standard breaker configuration is supplied \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ewithout line and load lugs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e unless terminals are specifically shown in the product photographs or stated in the selected product condition.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cspan\u003eSiemens catalog number: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSCMD69800ANGT\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSiemens Sentron molded-case circuit breaker\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eType: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSCMD\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eRated current: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e800 amps\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eNumber of poles: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eMaximum voltage: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e600 Vac\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eInterrupting rating: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e65 kAIC at 480 Vac\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDigital solid-state electronic trip\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eLSIG protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLong-time overload protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eShort-time protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstantaneous short-circuit protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGround-fault protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBolt-on mounting\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh-interrupting-capacity design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCurrent-limiting breaker design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLine and load lugs not included unless otherwise stated\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSiemens\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSiemens\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSentron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCatalog Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSCMD69800ANGT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBreaker Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSCMD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMolded-Case Circuit Breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmpere Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e800A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThree Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600 Vac\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterrupting Rating at 480V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e65 kAIC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Solid-State Electronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Functions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLSIG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Style\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBolt-On\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Power Distribution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWhat Does LSIG Mean?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Siemens SCMD69800ANGT provides four electronic protection functions:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eL — Long Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvides overload protection when current remains above the selected long-time pickup setting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eS — Short Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvides adjustable short-time protection and can support selective coordination between upstream and downstream protective devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eI — Instantaneous\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTrips the breaker rapidly during high-level short-circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eG — Ground Fault\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvides ground-fault protection when the breaker and electrical system are correctly configured.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAll trip settings must be selected by a qualified electrical professional based on conductor sizes, available fault current, equipment ratings, and the project coordination study.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTypical Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Siemens SCMD69800ANGT may be suitable for properly engineered and compatible:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eSiemens switchboards\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial distribution systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMain distribution sections\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFeeder breaker sections\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommercial electrical equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManufacturing facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCustom breaker enclosures\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplacement and retrofit projects\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh-capacity industrial feeders\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThree-phase power-distribution systems\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCompatibility must be confirmed before ordering. Matching the amperage and voltage alone does not guarantee that the breaker will fit the existing equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCompatibility Information Required\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor compatibility review, provide Ampstate with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eExisting breaker catalog number\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eComplete switchboard nameplate\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePhotographs of the installed breaker\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFront and rear breaker photographs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBus connection arrangement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounting hardware configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRequired line and load lugs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRequired trip settings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRequired control accessories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAvailable fault-current rating\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEquipment voltage and system configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTerminals and Accessories\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe standard Siemens SCMD69800ANGT breaker is generally supplied without terminals. Before ordering, confirm whether the installation requires:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eLine-side lugs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad-side lugs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBus connection hardware\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounting hardware\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuxiliary switches\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eShunt trip\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUndervoltage release\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBell alarm contacts\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGround-fault sensing components\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNeutral current transformer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHandle or operating mechanism\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOnly accessories specifically stated in the product listing or visible in the individual product photographs are included.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Condition\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eNew Surplus\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn unused genuine Siemens breaker obtained from surplus inventory. Original packaging, manufacturing date, labels, and cosmetic condition may vary.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eReconditioned\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA previously installed breaker that has been inspected, cleaned, mechanically operated, and electrically tested according to Ampstate’s applicable inspection process.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual product photographs should be used whenever possible because terminals, accessories, trip settings, labels, and cosmetic condition may vary between individual breakers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eImportant Ordering Notice\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cspan\u003eCatalog number \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSCMD69800ANGT\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e800A rating\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThree-pole configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e600V system compatibility\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRequired 65kAIC rating at 480V\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBolt-on mounting arrangement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRequired LSIG trip functions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRequired terminals and lugs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEquipment bus configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBreaker dimensions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRequired accessories\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDo not install this breaker based only on a visual match. The application must be reviewed by a qualified electrical professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Purchase From Ampstate?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAmpstate supplies industrial circuit breakers, MCC buckets, switchgear components, bus plugs, disconnect switches, panel-mounted switches, and hard-to-find electrical equipment throughout Canada and the United States.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eTechnical product review available\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNew-surplus and reconditioned options\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrical testing options\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFast RFQ support\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExpedited shipping options\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCanada and United States delivery\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupport for obsolete and hard-to-find equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAccessories and installation hardware available upon request\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAmpstate Electric Corporation\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePhone:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e +1 877-780-4466\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eEmail:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"mailto:sales@ampstate.com\"\u003e\u003cspan\u003esales@ampstate.com\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is the amperage of the Siemens SCMD69800ANGT?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Siemens SCMD69800ANGT is rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e800 amps\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHow many poles does the SCMD69800ANGT have?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIt is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ethree-pole circuit breaker\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed for three-phase electrical-distribution applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is the voltage rating?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe breaker is rated for operation at up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e600 Vac\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is its interrupting rating at 480 volts?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Siemens SCMD69800ANGT has an interrupting rating of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e65 kAIC at 480 Vac\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the SCMD69800ANGT have an electronic trip unit?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. It uses a digital solid-state electronic trip system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes this breaker provide ground-fault protection?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its LSIG trip functions include long-time, short-time, instantaneous, and ground-fault protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIs the SCMD69800ANGT bolt-on or draw-out?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIt is identified as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebolt-on molded-case circuit breaker\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAre line and load lugs included?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe standard configuration is generally supplied without lugs. Confirm the actual product photographs and listing details before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan it replace another Siemens 800A breaker?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePossibly, but direct interchangeability is not guaranteed. Confirm the breaker family, mounting style, bus connections, dimensions, interrupting rating, trip functions, terminals, and accessories.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes Ampstate ship this breaker to the United States?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. Ampstate can arrange shipping throughout Canada and the United States, subject to stock availability and destination.\u003c\/span\u003e\u003c\/p\u003e","brand":"Ampstate Electric","offers":[{"title":"Default Title","offer_id":44371960660034,"sku":null,"price":7000.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0613\/8783\/3410\/files\/SCMD69800ANGT.png?v=1784646913","url":"https:\/\/ampstate.ca\/products\/siemens-scmd69800angt-800a-3-pole-600v-lsig-circuit-breaker","provider":"Ampstate Electric","version":"1.0","type":"link"}